繼電器常用術語-1

發布日期:2022-04-26 點擊率:189

交流線圈(AC-coil

采用AC交流直接激活的繼電器輸入線圈,如果沒有特殊說明,通常用50 Hz電源的Vrms 表示。


相鄰觸頭(Adjacent contacts

兩個不互相聯通相鄰觸點回路(繼電器極)之間的絕緣參數,絕緣等級取決于繼電器設計,額定電壓和周圍環境條件。


環境溫度(Ambient temperature

繼電器附近(距離根據IEC 61810-1)的溫度。最低環境溫度和最高環境溫度傳感器網" href="http://m.lqeedmx.cn/category.asp?categoryid=341" target="_blank">溫度傳感器網" href="http://m.lqeedmx.cn/jscontent.asp?id=56&categoryid=67" target="_blank">溫度傳感器網" href="http://m.lqeedmx.cn/category.asp?categoryid=341" target="_blank">溫度是指繼電器和附件能正常工作最低工作溫度和最高工作溫度。繼電器正常工作應不超過此溫度范圍內,在指定的溫度范圍內工作,環境溫度不會影響電氣壽命。環境溫度范圍參照IEC 61810-1,并且用°C表示。除另有說明外,環境溫度一般為23℃。


Approvals

With the approval label the independent approval agency and/or test house confirms the compliance with the relevant product standards and/or certain product characteristics.


BEAB

British Electrotechnical Approvals Board, England


CE

Conformité Européenne, marking for specific products relating to product safety in accordance to European Laws


CQC

China Quality Certification Center, Peoples Republic of China


CSA

Canadian Standards Association, Canada


DEMKO

Danmarks Elektriske Materielkontrol, Denmark


FIMKO

Sähkötarkastuskeskus Elinspektionscentralen, Finland


KEMA

Naamloze Vennootschap tot Keuring van, Electrotechnische Materialien, Netherlands


LLOYD's

Lloyd's Register of Shipping


NEMKO

Norges Elektriske Materiellkontroll, Norway


ÖVE

Österreichischer Verband für Elektrotechnik, Austria


SEMKO

Svenska Elektriska Materiellkontrollanstalten AB, Sweden


SEV

Eidgenössisches Starkstrominspektorat, Switzerland


TÜV

Technischer Überwachungs-Verein, Germany


UL

Underwriters Laboratories, Inc., USA; UL Component Recognition Mark for the United States


UL

UL Component Recognition Mark for Canada


UL

UL Component Recognition Mark for the United States and Canada


VDE

VDE-Prüfstelle, certificate of conformity with factory surveillance, Germany

Bandwidth

The range of frequencies for which the performance falls within the specified limits.


Bifurcated contact

see > Twin contact.


Bistable relay, latching relay

In a bistable or latching relay the contacts remain in the last switching position once the coil input voltage is disconnected.

Even though the bistable relays are leaving production preferably in reset contact position, the position of the contact (set position/reset position) is not defined at delivery. The user needs to check the contact position and to set/reset the relay to the required position.

Bistable relays only require a short set respectively reset pulse and do not need any energization once the switching position changed. Unless otherwise stated the bistable relays can endure a permanent energization.

Note: For some relay series a permanent coil power supply is not permitted; in this case the maximum energization duration or the required coil power reduction is indicated in the respective datasheet.


Bistable relay, switching characteristics

In a bistable relay, the contacts remain in the last switching position after the input voltage is disconnected.

Note: Unless otherwise stated the position of the contact (set position/reset position) is not defined at delivery, the customer needs to check the contact position and to set/reset the relay to the required position.

Note: Unlike monostable relays which return to their predefined contact rest state in case of power supply break down and thus might be showing a fail safe behavior, bistable relays do not automatically return to such predefined position. Therefore the application and relay control has to be designed to cover such situations and bistable relays should not be used in applications that are rated according to ISO/TS 16949 7.5.3 'Product Identification and Traceability'.


Bounce

An unintentional phenomenon that can occur during the making or breaking of a contact circuit when the contact elements touch successively and separate again before they have reached their final position.


Bounce time

The time from the first to the last closing or opening of a relay contact. Unless otherwise stated the indicated times are maximum values and are for energization with rated voltage, without any components in series or parallel to the coil, and at reference temperature. Also see > Relay cycles.


Breaking capacity max.

Product of the switching current and switching voltage (in W for direct current, in VA for alternating current). Also see > DC breaking capacity


Bridging contact

Double contact configuration, where two movable contacts are mechanically connected and operate simultaneously. In a bridge configuration, the load current flows from one stationary contact via the bridge to a second stationary contact. See also table Contact arrangement. See > Form X contact, Form Y contact, Form Z contact.

下一篇: PLC、DCS、FCS三大控

上一篇: 索爾維全系列Solef?PV

主站蜘蛛池模板: 福利视频国产 | 欧美丰满熟妇aaaaa片 | 日韩av一区二区三区免费看 | 老熟女一区二区免费 | 久久午夜无码鲁丝片午夜精品 | 久久久久成人片免费观看蜜芽 | 亚洲毛片免费视频 | 国产区在线免费观看 | 丰满岳乱妇一区二区三区 | 一本久道热中字伊人 | 成人免费网站视频 | 成人午夜视频一区二区国语 | 男人把女人桶到爽免费应用 | 天天碰天天干 | 亚洲在线免费观看视频 | 欧美日韩一区二区综合 | 大地资源网在线观看免费官网 | 密桃av| 亚洲欧美一区二区三区二厂 | 国产精品原创巨作av | 韩国电影一区 | 四虎精品永久在线 | 亚洲成人中文 | 日本一片免费观看高清完整 | 亚洲综合日韩在线亚洲欧美专区 | 国产精品视频一区二区三区w | 日韩中文字幕视频在线观看 | 亚洲精品午夜一区人人爽 | 成a人片亚洲日本久久 | 18勿入网站免费永久 | 亚洲高清无码加勒比 | 在线一区观看 | 天天综合色天天综合色sb | 岛国片人妻三上悠亚 | 国产一区二区在线观看免费 | 国产高清美女一级a毛片久久 | 国产欧美精品国产国产专区 | 日韩视频www | 国产福利视频奶水在线 | 日本精品一区二区三区在线观看 | 无套内内射视频网站 |